Ultrasonic welding machine common fault problems and treatment methods
Ultrasonic welding machine
common fault problems and treatment methods
Ultrasonic welding machines
have some common faults, and many of them are troubled by this. Now Altrasonic
shares with you how to deal with these problems, hoping to help everyone solve
their troubles.
1. turn on the power without
display
Reasons: The fuse is blown
Solution: 1. Check if the
power tube is short-circuited; 2. Replace the fuse.
2. the ultrasonic test has
no current display
Reasons: 1. The power tube
is burned; 2. The high voltage capacitor is burnt; 3. The relay control line is
faulty.
Solution: Replace the burned
parts.
3. the acoustic wave test
current is too large, overload
Reasons: 1. The welding head
is not locked or cracked; 2. If there is no welding head, the current is large,
the transducer or the secondary rod is aged or cracked; 3. The power tube
characteristics are mutated or burnt; 4. Power The amplifier circuit is
defective.
Solution: Replace the
relevant parts.
4.the current is too large
when welding, overload
Reasons: 1. The air pressure
is high; 2. The welding head is too large, and the inrush current is large; 3.
The triggering pressure is high and the delay time is long; 4. The secondary
rod ratio is high.
Solution: 1. Reduce the air
pressure; 2. Use a larger power model; 3. Reduce the trigger pressure and
reduce the delay time; 4. Switch to a low-multiple secondary rod.
5. the trigger switch
welding head does not fall
Reasons: 1. The emergency
stop switch is not reset; 2. The trigger switch cannot be triggered at the same
time or one of the contacts is bad; 3. The program control board has a problem.
Solution: 1. Reset the
emergency stop switch; 2. Detect that both trigger switches can be triggered at
the same time; 3. Check the program board to troubleshoot, generally IC
problem.
6. After the trigger switch,
the ultrasonic time is very long or the holding time is very long.
Reasons: The welding time or
the holding time band switch is open.
Solution: Adjust the band
switch contacts to make them in good contact.
7. After the trigger switch,
the ultrasonic wave cannot be triggered.
Reasons: 1. The pressure
trigger switch is damaged; 2. There is a problem with the program board.
Solution: 1. Replace the
pressure trigger switch or small spring; 2. Check the program board to
troubleshoot, generally it is an IC problem.